Dear Sankarsan,
After the changes done in PCR, it is processing in time evaluation as below for three different IN time :
I have taken your Time type 1001=9012 (Daily working hours), Time type 1002=9013(Shortfall hours) & Time type 1003=9014 (Daily working hours-only for storage). Am i understood correctly?
1. when IN time is 8:45
and in this case, ZES table Time type 9014 and 9013 both are showing 9.50 hrs which is wrong because he worked from 8:45 to 18:30 it means 9:30 hours (calculation should start from 9:00 am). So time type 9012 should show 9 hrs working and time type 9013 should show no shortfall hours(no value)
2. when IN time is 9:15
and in this case, ZES table Time type 9012 is showing 9.25 working hours which is correct because he worked 9.25 hours, but Time type 9013 is also showing 9.25 hours shortfall which is not correct.
3. when IN time is 10:30
and in this case, ZES table Time type 9013 is showing 1.00 hours shortfall which is correct because he worked only 8 hours. But didn't display Time type 9012 for working hours.
Pls suggest.
Best Regards,